ro-localization

Range-only localization with a particle filter, for robots measuring ranges to fixed radio beacons (e.g. UWB) at known positions. Unlike plain Monte Carlo localization (pf-localization), each particle also estimates a bias for every beacon, which may change suddenly over time (e.g. because of non-line-of-sight propagation). The particles are implemented by a CPosePDFParticlesExtended class inside the app. For the method, see https://www.mrpt.org/paperuwb-particle-filter-localization/

Usage

ro-localization <config_file.ini>

Example

cd modules/mrpt_data/config_files/ro-localization
ro-localization UWB_localization_demo.ini

A 3D window shows the beacons, the particles and the estimated path while the dataset is processed.

Configuration file

  • [ro-localization] :

    • rawlog_file : the dataset, with odometry and mrpt::obs::CObservationBeaconRanges observations.

    • gridmap_file : optional grid map (.gridmap), only for display.

    • groundTruthFile : optional ground truth path, to compute errors.

    • logOutput_dir : prefix of the output directories.

    • 3DSceneFrequency : save a 3D scene every N steps.

    • experimentRepetitions, random_seed (0: randomize from the current time).

    • Pc_range_ini, Pc_range_end, Pc_range_step : optional sweep of the probability of a bias change, to run one experiment per value.

    • SAVE_3D_TO_VIDEO : grab the 3D window frames to image files.

  • [RO_MODEL] : the bias model: probabilityChangingBias (probability of a bias change at each step), changingBiasUnifRange (range of the uniform distribution of new biases), mixtureProposalRatio.

  • [OdometryEstimation] : initial robot pose (odometry_X, odometry_Y, odometry_PHI in degrees), in the beacons reference frame.

  • [PF_options] : particle filter options; sampleSize is the number of particles (mrpt::bayes::CParticleFilter::TParticleFilterOptions).

  • [KLD_options] : KLD adaptive sample size parameters.

  • [MetricMap] and [MetricMap_landmarksMap_00_*] : the reference map with the beacon IDs and positions (nBeacons, beacon_NNN_ID, beacon_NNN_{X,Y,Z}) and the range likelihood options.

Output

In <logOutput_dir>_Pc_<value>/REP_NNN/, for each repetition: 3Dscene_NNN.3Dscene (3D views every 3DSceneFrequency steps), particle_matrix.txt (estimated pose, its covariance, the ground truth pose and the estimated beacon biases at each step), and GT_ranges.txt and GT_offsets.txt (ranges computed from the ground truth, and measured minus ground truth ranges). When sweeping Pc_range_*, the mean and standard deviation of the position error for each value are appended to Pc_<ini>_<end>_RESULTs.txt.

See also